High Precision OTDR
Model: FF-980PRO Wavelength: 1310/1550nm
Dynamic Range: 22/20dB Testing Range: 3m to 60km
The OTDR Comes with All Functions
1) Visual Fault Locator (VFL) Function
2) Optical Power Meter Function
3) Optical Light Source Function
4) Touch Screen
5) PC Software for Testing Report Printed or Save as PDF
6) Calibrate Certificate
7) SC FC ST Connectors
CONTACT SALES ENGINEER 7/24 IF ANY QUESTIONS
sales(@)firstfiber.cn
Wechat/ Whatsapp: +86 18217747005
Skype ID: anker.yang88
Professional Equipment For FTTx & Metro Optical network Systems
As fiber optics plays more and more important role in modern telecommunication and CATV networks, the requirements to the construction, test and maintenance of fiber optics links also become more prominent.
FF-980PRO is a unique product mainly designed for construction and maintenance of telecommunication and CATV networks. The FF-980PRO OTDR can be widely used in engineering construction, maintenance test and emergency repair of all fiber optics related systems. Comparing with a regular OTDR, the FF-980PRO OTDR is more compact in size and easier for field use.
FF-980PRO OTDR handheld design, compact and lightweight, easy to carry. Event information through TFT color display and data storage capabilities. Through the USB interface, the test data can be uploaded to the PC, to facilitate the post-processing, archiving and printing.
Package includes
- 1x OTDR,
- 1x FC Connector
- 1x SC Connector
- 1x ST Connector,
- 1x User Manual
- 1x USB Cord
- 1x OTDRviewer Software,
- 1x Power Charging Adapter
- 1x Carrying Case,
- 1x Certificate of Calibrate
General | |
Display | IPS Touch Screen, 800x400px, 4 inch |
Interface | 1×USB, 1xOTDR port, 1xVFL port, 1xPower Meter Port, 1xCharging Port |
Power Supply | 7.4V/4400mAH(dc), 100V(ac) to 240V(ac), 50~60Hz |
Battery | Lithium battery (with air traffic certification) Operating Time:8 hours, Telcordia GR-196-COR |
Power Saving | Backlight off, Auto shutdown |
Data Storage | Internal memory: 200 curves |
Language | English in default |
Environmental Conditions | Operating temperature and humidity: -10℃~+50℃, ≤95% (non-condensation) Storage temperature and humidity: -20℃~+75℃, ≤95% (non-condensation) Proof: IP65(IEC 60529) |
Test parameter | |
Pulse Width | 5ns to 20us |
Distance Range | 3m to 60km |
Sampling Resolution | Minimum 16cm |
Sampling Point | Maximum 65K |
Linearity | ≤0.05dB/dB |
Distance Accuracy | ±(1m+measuring distance×2×10^-4+sampling resolution ) ( excluding IOR uncertainty) |
IOR Setting | 1.0000~2.0000 |
Units | km, kft, ft |
OTDR Trace Format | Telcordia universal, SOR, issue 2(SR-4731) OTDR: User selectable automatic or manual set-up |
Fiber Event Analysis | User defined PASS/FAIL thresholds: -Reflective and non-reflective events: 0.01 to 1.99dB (0.01dB steps) -Reflective: 0.01 to 32dB (0.01dB steps) -Fiber end/break: 3 to 20dB (1dB steps) |
Visual Fault Loctor (VFL) | |
Wavelength(±20nm) | 650nm |
Output Power | 10mW,CLASSII B |
Range | 15km |
Optical Power Meter | |
Wavelength | 850/1300/1310/1490/1550/1625nm |
Testing Range | -70dBm ~ +10dBm |
Accuracy | |
Light Source | |
Wavelength | 1310/1550nm |
Power Level | -5dBm |
Accuracy | ±0.04@20℃@15min |
You may also be interested in the following product(s)
2.5mm Male to 1.25mm Female Adapter |
FC Female to SC Male Adapter |
SC Female to ST Male Adapter Cable Jointer |
ST Female to LC Male Adapter |
Frequently Asked Questions on OTDR
Model# FF-980PRO
Q1: Does the OTDR (FF-980PRO) support both 1310nm and 1550nm wavelength to test fibers?
A1: Yes, the OTDR support both 1310nm and 1550nm wavelengths. You can switch these two wavelengths on parameter setting easily.
Q2: Does the OTDR (FF-980PRO) support real time and average time testing mode like other famous OTDR?
A2: Yes, the OTDR support both read time and average time testing mode.
Q3: Does the test result can be displayed quickly on screen?
A3: Yes, very quickly. If you selected "Auto" testing mode, it takes 3 to 5 seconds to display OTDR curves and event list on screen. When testing mode stays in "manual" mode, you can set the average time to 15 seconds, 30 seconds, etc...
Q4: What connectors do come with the OTDR?
A4: The OTDR comes with FC, SC and ST connectors in default. LC connector is sold separately.
Q5: My fiber cable is with a APC connector, but I have bought an OTDR with UPC connector(port). How can I make the test?
A5: According to industrial standard, APC connector can not work together with UPC connectors. So (1) please find a short fiber patch cord, one end is with APC and the other end is with UPC. (2) Use the UPC to APC adapter. See the picture. (3) buy an OTDR with APC connector(port). Please let our sales know you are going to buy an OTDR with APC connector before you place your order.
Q6: Do I need to add money for extra functions (VFL, OPM, OLS, Touch Screen) ?
A6: No. The OTDR comes with all of these functions.
Q7: Do the OPM and OLS function can turn on same time?
A7: No, When you turn on OLS, OPM turns off automatically. And when you turn on OPM, OLS will turn off automatically. That means the device itself can NOT test its laser value.
Q8: The OTDR can work on short cables, e.g. 3 meters ?
A8: Yes. See the video please. https://fiberoptics.wistia.com/medias/iydo93h7yg
Q9: Do you have a video demo?
A9: Yes, watch the video please. https://fiberoptics.wistia.com/medias/epnidto4m5
Q10: How to re-calibrate the OTDR, and any fees charged for re-calibration?
A10: The OTDR has been already built-in self-calibration system for Touch Screen Recalibration. So, you can re-calibrate screen easily. If testing calibration needed to be deployed, OTDRs should be sent back China.
Customer pays for shipping fees to China while we pay shipping fees to customer. But within warranty time (3 years), customer does not need to pay any fees. And no other fees will be charged for calibration or repair work.
Q11: What is your warranty time and repair policy?
A11: If software problems, we can send you a firmware for system upgrade by email. If a hardware problem, our engineers can cooperate with you to find which part is broken in OTDR via email or skype video. And we send you the hardware parts, and teach you how to repair. But if it is not easy to repair from your side, you must return back for repair.
Customer pays for shipping fees to China while we pay shipping fees to customer. But within warranty time (3 years), customer does not need to pay any fees. And no other fees will be charged for calibration or repair work.
Q12: Does the OTDR FF-980PRO support active (live) fiber testing?
A12: No. For active fiber testing, 3 wavelengths’ OTDR is a must. Another model FF-990PRO-T2 is for active fiber testing. Visit the link please. http://www.firstfiber.cn/ff-990pro-t2.html
Q13: Why does Event List disappear some times?
A13: Please check your software version. If version number is before VT2.55, please contact us at sales@firstfiber.cn to get an upgrade-package. You can update its software easily.
Q14: Why are there no test result when far end of fiber cable with APC connector?
A14: Please check your software version. If version number is before VT2.59, please contact us at sales@firstfiber.cn to get an upgrade-package. You can update its software easily.
Q15: Does the OTDR can generate .sor file and print out testing report?
A15: Yes. Like any other normal OTDR. The FF-980PRO can generate .sor files, and users can print testing report via PC software.
Q16: Could you provide technical support or training service on the OTDR?
A16: Yes, I can help if you have any question on the OTDR.
Q17: Could you make OEM service? I want to make my logo on your OTDR?
A17: Yes, of course. Please contact our sales team.
Warranty Service:
FirstFiber warrants to the purchaser that our products shall be free from defects in material and workmanship under normal use (consumables, normal tear and wear excluded) for a period of one year from the date of shipment. Any part which is determined by FirstFiber to be defective in material or workmanship shall be returned to FirstFiber or authorized service location, as FirstFiber designates and shipping costs prepaid. Defective items will be repaired or replaced at FirstFiber's option.
ISO9001:2008 The certificate shows that a component/subsystem can be used in a specific application according to a requirement class (RC) or a integrity level (SIL). The system integrator and end user must always be aware of how to use certified components/subsystems in safety-related function, respectively a safety instrumented system. Because of the many different possibilities and how to configure a safety system, the end user must get the related information from the manufacturer of the certified component/subsystem. |
CE The CE marking is a mandatory European marking for certain product groups to indicate conformity with the essential health and safety requirements set out in European. To permit the use of a CE mark on a product, proof that the item meets the relevant requirements must be documented. |
|||
RoHS Working in partnership with the policy lead at BERR (The Department for Business, Enterprise & Regulatory Reform), NWML is the UK Enforcement Authority for the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment Regulations 2008 (the “RoHS Regulations”). Manufacturers need to understand the requirements of the RoHS Directive to ensure that their products, and their components, comply. |
FCC The Federal Communications Commission (FCC) is an independent United States government agency. The FCC was established by the Communications Act of 1934 and is charged with regulating interstate and international communications by radio, television, wire, satellite and cable. The FCC's jurisdiction covers the 50 states, the District of Columbia, and U.S. possessions. |