Sales@FirstFiber.cn
Search Site

CL1400A Pipeline and Cable Locator, with inductive clamp, stethoscope and fault finding holder

SKU: 1907212321

 Sales Rep   sales@FirstFiber.cn  Tech Support  tech@FirstFiber.cn

CL1400 Pipeline and Cable Locator consists of a Transmitter, a Receiver and Accessories, used in the underground pipeline & cable route accurate locating, the burial depth measuring, long distance tracing, and insulation fault point detecting. We adopted multicoil electromagnetism technology in CL1400 Pipeline and Cable Locator, enhanced the precision of the pipeline and cable location and the burial depth, and the goal pipeline identification capability. It could accurately carry on tracing and location to the goal pipeline and cable in the crowded pipelines and cables.
CL1400 Pipeline and Cable Locator is widely used in the telecommunication, mobile, electric power, water supply, natural gas, physical prospecting, petrochemical and city construction, etc.

Functions
1. Detect the route of underground pipeline and cable
2. Measure the burial depth of underground pipeline and cable
3. Detect and locate the insulation fault point of the underground pipeline and cable
4. Identify the goal pipeline and cable under multiple underground pipelines and cables situation

Features
1. Adopt the advanced signal processing technology and the latest integrated circuit to achieve outstanding test performance.
2. The detecting signal transmission method includes:
(1) Injection method: with injected the spot on the pipeline to detect the route and the burial depth, this method measuring accuracy is high, and good anti-jamming ability.
(2) Clamping method: used in a pipeline with the exposed section and easy to clamp.
(3) Induction method: used in a pipeline without injection point or without exposed section.
3. Many kinds of detecting frequency: 480Hz, 7.7KHz , 31KHz and 61KHz, which are four kinds of active frequency and 50Hz of passive frequency using in electric cable; The user may carry on the choice according to the different environment (need special detecting frequency please indicate specially in order contract).
4. Enhancement test efficiency by different localization pattern and function:
(1) peak value pattern: Determines the position through the maximum route signal.
(2) valley value pattern: Determines the position through the minimum route signal
(3) route direction detection: Direct-viewing, instructs the route rapidly the direction.
(4) insulation fault finding (FF): Detect and locate the insulate fault point of pipeline and cable .
(5) Stethoscope: find loading signal on the pipeline through stethoscope from the multitudinous pipelines.
5. Auxiliary functions:
(1)  Automatic control receive gain: The automatic control receiver gain can keep the receiver to be at the optimized status and avoid manual operation.
(2) Sound function: The receiver reflects the detecting signal intuitively through the tonality changing.
(3) Check the detecting condition: When the transmitter in injection mode, first test the insulation resistance and the residual voltage of pipeline, then load the signal to a pipeline. When the value of the insulation resistance too small (almost in short-circuits) the transmitter will withdraw automatic from this mode, when the residual voltage is so large the transmitter will warn, the operator must stop to load signal and shut off the transmitter.
(4) Battery value testing: Real-time detection of battery, when the voltage lower than the protect value, the transmitter will warn and automatic shut-down.
(5) Power save: The machine will be off to save the power if the transmitter is not be operated after booting in 30 second, and if the receiver is not be operated after booting and no other keystrokes about 10 minutes.


Specification

Transmitter:
Signal Frequency for Injection Method 480Hz, 7.7KHz, 31KHz, 61KHz
Signal Frequency for Induction Method 31KHz, 61KHz
Signal Frequency for Clamping Method 31KHz
Signal Frequency for Fault Finding 480Hz
Output Voltage 0-400Vp-p adjust according to the insulation condition
Output Wave Shape  sine wave
Power Supply 11.1VDC 4.4AH Li-battery
Maximum Output Power  10W
Receiver:
Power Loss <1W
Power Supply 11.1VDC 1.8AH Li-battery
Max. Burial Depth for Detecting 4.5 meters (normal condition) 
Tolerance of burial Depth for Detecting ±0.05H ±5cm (“H” is pipeline burial depth)
Tolerance of Route for Detecting ≤5cm
The Effective Length under Detecting
Pipeline Route and Depth with Injection Method
≥10Km (normal condition)
The Effective Length under Detecting
Pipeline Route and Depth with Induction method
≥3Km (normal condition)                                          
The Effective Length under Detecting
Pipeline Route and Depth with Clamping method
≥6Km (normal condition)                                               
Insulated Fault Detecting ≥2 MΩ
Environmental: 
Operating Temperature   -20℃~+50℃ 
Storage Temperature -40℃~+70℃ 
Relative Humidity    10%~90%
Atmospheric Pressure   86~106KPa
Environmental Noise ≤60dB
Weight and Dimension: 
Name Weight (Kg) External Dimensions (mm)
Transmitter 3.4 348×239×175
Receiver 2.6 648×260×130
Entire Machine (Gross Weight) 14 790×250×420
Optional Accessories:
Name Weight (Kg) External Dimensions (mm)
Fault Finding Holder 1.5 525×672×25

 

 

1. Injection method:
Injection method is fit for the application that can find the electrical connection points on the goal pipeline and cable, such as optical cable outlet and the bolts of metal pipeline, etc.

2. Induction method:
Induction method is used in a pipeline without injection point or without exposed section.

3. Clamping Method:
Clamping method is used in a pipeline with the exposed section and easy to clamp.

 

Use spaces to separate tags. Use single quotes (') for phrases.

Warranty Service:
FirstFiber warrants to the purchaser that our products shall be free from defects in material and workmanship under normal use (consumables, normal tear and wear excluded) for a period of one year from the date of shipment. Any part which is determined by FirstFiber to be defective in material or workmanship shall be returned to FirstFiber or authorized service location, as FirstFiber designates and shipping costs prepaid. Defective items will be repaired or replaced at FirstFiber's option.

firstfiber_warranty

ISO9001:2008

The certificate shows that a component/subsystem can be used in a specific application according to a requirement class (RC) or a integrity level (SIL). The system integrator and end user must always be aware of how to use certified components/subsystems in safety-related function, respectively a safety instrumented system. Because of the many different possibilities and how to configure a safety system, the end user must get the related information from the manufacturer of the certified component/subsystem.

          firstfiber_warranty

CE

The CE marking is a mandatory European marking for certain product groups to indicate conformity with the essential health and safety requirements set out in European. To permit the use of a CE mark on a product, proof that the item meets the relevant requirements must be documented.

 
         
firstfiber_warranty

RoHS

Working in partnership with the policy lead at BERR (The Department for Business, Enterprise & Regulatory Reform), NWML is the UK Enforcement Authority for the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment Regulations 2008 (the “RoHS Regulations”). Manufacturers need to understand the requirements of the RoHS Directive to ensure that their products, and their components, comply.

  firstfiber_warranty

FCC

The Federal Communications Commission (FCC) is an independent United States government agency. The FCC was established by the Communications Act of 1934 and is charged with regulating interstate and international communications by radio, television, wire, satellite and cable. The FCC's jurisdiction covers the 50 states, the District of Columbia, and U.S. possessions.